Wind turbine

VTSZ: 85 01 61 20 vertical axis wind turbine support structure

Rated power: 1000W Blade: 3 out wind speed: 1m / s Minimum charge wind speed: 3m / s Nominal wind speed: 13m / s Survival wind speed: 60m / s Output voltage: 24VDC Weight: 160 kg Voltage: -30 °C - 50 °C with charging controller

3-phase, nutritious, high-efficiency transformer inverter 12770W heading 8504 4097

Most popular in the 3-12 kW range for maximum efficiency of 95.9%, the Fronius IG Plus reaches one of the highest efficiency among the inverters

DC maximum power cos φ = 12770 W
Max input current (IDC max) of 55.5 A
min input voltage (UDC min), 230 V
Voltage Feed-in starts (UDC start) 260 V
Rated input voltage (UDC, r) 370 V
max input voltage (UDC max) 600 V
MPP voltage range (Umpp min - max Umpp) 230-500 V
Output data:
Nominal AC power (Pac, r) 12000 W
Max 12000 VA Output Power
Max current output (IAC max) 17.4 A
grid connection (UAC, r) WO 3 ~ 400 V / 230 V
Min output voltage (UAC min), 180 V
max output voltage (UAC max) 270 V
Frequency (fr) 50 Hz / 60 Hz
frequency range (fmin - fmax) 46 Hz - 65 Hz
Distortion factor Power factor (cos φac, r) from 0.85 to 1 ind. / Main.

GENERAL DATA
Dimensions (H x W x D) 1263 x 434 x 250 mm
Weight 49.2 kg
Enclosure IP 54 2)
Safety Class: 1
Overvoltage category (DC / AC) 2/3
Night consumption Inverter concept HF transformer
cooling Air cooling down